Hydroponics and Grow Lights
  HumboldtHydroponics.com >> 1371    Cart Contents  |  Checkout  |  Contact Us  
  Search

  Categories 

 Additives 
 Apparel 
 Books 
 Carbon Dioxide 
 Climate Control 
 Cloning 
 Ducting 
 Fans and Blowers 
 Foliar Feed 
 Fungicide 
 Grow Lights 
 Growing Mediums 
 Hydoponic Systems 
 Hydro Accessories 
 Light Movers 
 Lighting Controllers 
 Misc. 
 Nutrients 
 Odor Control/Air Quality 
 Organic and Natural Nutrients 
 Pest Control 
 pH and TDS 
 Reflective Materials 
 Timers 
  Information 

 Contact
 Policies
 Help
 Guarantee
 
Item: 1371 
Microclimate Controller System (MCC-1)
Microclimate Controller System (MCC-1)
The Micro Climate Controller MCC-1 is designed to perform all the major atmospheric and timed functions required in an automated growth environment including temperature, humidity, carbon dioxide enrichment, lighting and irrigation control. The controller incorporates an external coil cooling thermostat , a dehumidifying humidistat, a 24-hour clock timer, a photo-sensor and a repeat cycle timer. Heating and humidifying control is provided by triggers for remote high-amperage relays which enable synchronized equipment management. Automatic override and defeat systems coordinate controls to consider all possible variables. The MCC-1 is enclosed in a black anodized, brush finish aluminum housing. An attractive screen-printed front panel with function indicator lights makes system monitoring and adjustment quick and easy. All connections are standard 3-prong grounded plugs and receptacles. No hard wiring is required for basic operations. Low and high voltage relays are available to operate auxiliary equipment. Every aspect of the growing environment may be addressed by the Micro Climate Controller (MCC-1). Operates on 110VAC with 15 Amp switching capacity. The MCC-1 was designed to be used independently or in conjunction with Green Air Products function relays. The MCC-1 will serve independently for systems and equipment requiring 110 VAC of 15 Amps or less. Plug power cord into standard wall outlet and locate controller where good air circulation represents plant zone conditions. Plug exhaust fan into exhaust outlet. Set thermostat and humidistat dials to maximum desired values. Fan will operate when conditions exceed those set points. Function indicator lights will display the condition and outlet status. CO2 equipment can be operated from the CDDS-1 trigger when using the CDMC-2 infrared monitor controller. This outlet provides an exhaust synchronized override feature to delay enrichment during ventilation periods. When timed control is desired plug CO2 equipment into CO2 outlet and set timer mode toggle switch accordingly. Set the sequence timer duration dial for minutes of "On" time and frequency dial for the time between "On" functions Exhaust demand will override CO2 production and timer will reset to cycle immediately following ventilation. CO2 outlet is defeated by a built-in photo sensor to operate only when light is present. If not being used for CO2 enrichment the sequence timer can be used for a variety of other timing duties. Switch the mode toggle to "Cycle Timer" to bypass the exhaust and photoperiod defeat circuits. Timer "On" times as short as 5 sec. can be achieved to operate irrigation pumps or solenoids for all kinds of hydroponic and automatic watering systems. Plug thermostatically controlled heater into HR-1 relay trigger outlet. Exhaust operations will override heating trigger to defeat heaters. Use the HF-1 relay outlet for humidifiers to provide a comfort zone between humidifying and dehumidifying. The 24 hour clock timer is useful for all daily oriented timing operations. The 96 independent 15 min trippers allow any combination of on/off functions repeated each 24 hours. Lighting, fans, pumps and watering are only a few of the tasks this timer can perform. If your combined amperage draw exceeds 15 amp power handling capacity of the controller optional high amperage function relays can be used to provide service to large systems. Exhaust Outlet This outlet receives power when excess heat or humidity need to be ventilated. Intake and exhaust fans or other venting equipment can be automatically functioned according to the set-points on the thermostat and humidistat dial face. There is approximately five points differential between "On" and "Off" cycles to maintain a consistent air quality. CDDS-1 Trigger When using a CO2 monitor to determine and control CO2 producing equipment this outlet provides 24 hr. power which is defeated during exhaust functions to minimize CO2 loss. Plug CDMC-2 digital sequencer into this trigger to integrate CO2 management with atmospheric control. Timed Outlets These outlets are operated by the 24 hr. time clock. Use to function almost any electrical equipment according to time of day settings. This precision synchronous clock provides 96 independent 15 min. On - Off trippers. Use the HAR-1 relay for high amperage or voltage equipment. HR-1 Relay This feature provides power for heaters or heating relays. A small heater with built in thermostat can be plugged directly into HR-1 outlet. Larger units must use heating relay HR-1 to isolate high amperage requirements. Set heating thermostat to minimum allowable temperature and cooling thermostat to maximum high temperature. The span between these two settings is the comfort zone. The HR-1 relay outlet will not operate during exhaust functions. Cycle Outlet The cycle outlet utilizes the same internal short cycle timer and operates simultaneously with the CO2 outlet. When the photo sensor mode switch is in the cycle timer position the timer is not interrupted by the photo and exhaust defeat circuits. Both outlets will provide 24 hr. sequence timing for irrigation systems, pumps, solenoids, transformers, motors, relays and many other equipment devices. CO2 Outlet Carbon dioxide enrichment equipment can be precisely timed through this outlet by the on board cycle timer. This timer will repeat your pre-set "ON" and "Off" periods continuously whenever the photo sensor detects the presence of light. The duration of the "On" cycles are from 5 sec. to 30 min. and the frequency of "On" cycles ( or the "Off" time between them ) is from 7 min. to 8 hrs. The photo sensor mode switch must be in the CO2 timer position for photo and exhaust function defeat circuits. Reset feature will replenish CO2 immediately after exhaust cycle. Switch mode toggle to "Off" for manual reset. HF-1 Relay This outlet is similar in function to the HR-1 relay outlet except it is for humidity producing apparatus. Humidifying equipment can not function during dehumidifying cycles. IMPORTANT Make certain the combined amperage draw of all equipment operating through the MCC-1 does not exceed 15 amps. Use function relays to conduct high amperage or alternate voltage currents.


Price: $616.46
Qty.:

 Brands

 3D Organics 
 Advanced Nutrients 
 Age Old Organics 
 Aggrene 
 Agrosun 
 Air King 
 American Agritech 
 American Hydroponics 
 Atami 
 Aurora Innovations 
 Big Blue 
 BIOBIZZ 
 Blank Shirts 
 Botanicare 
 C.A.P. 
 Can Fan 
 Can Filters 
 Concern 
 CPR 
 Cutting Edge Solutions 
 Dayton 
 Deflecto 
 Down To Earth 
 Dyna-Gro 
 Earth Juice 
 Earthcrew 
 Eco Neem 
 Einstein Oil 
 Elicent 
 Emerald Triangle 
 Eurosystems 
 Eye 
 EZ-Clone 
 Fox Farm 
 General Hydroponics 
 Grasslin 
 Green Air Products 
 Green Planet 
 Greentrees Hydroponics 
 GRODAN 
 GROTEK 
 Gualala Robotics 
 Hanna Instruments 
 Hart & Cooley 
 HiGrow 
 Humboldt Flower Products 
 Hydro Organics 
 Hydrodynamics 
 Hydrofarm 
 International Horticulture 
 Ionic 
 Lakewood 
 Life Light Technologies 
 Lumatek 
 Max-Sea 
 Maxi-Jet 
 MicroHydro/Purefoods 
 Natures Control 
 Natures Technologies 
 NZ Hydro Int. 
 Oakton 
 Oasis 
 Olivia's 
 ONA 
 Organic Air 
 Phillips 
 Plant Success 
 Rambridge 
 Safer 
 Sea Pal Fish Products 
 Sparetime 
 Sunlight Supply 
 Sylvania 
 Technaflora 
 Trinidad Guano 
 Tropical Organics 
 Van Patten 
 Venture 
 Vitech 
 Whitney Farms 
 
Transactions Secured by
  
 
Copyright © 2001-2008 Humboldt Hydroponics, Inc. 

Green Air Products outlet timer CO2 equipment exhaust function cycle controller MCC-1 relays thermostat high photo relay amperage heating defeat operate Plug power